Navigation Menu

ENG: Resection of a deeply intramural large G2 myoma, looking like a G0 myoma at hysteroscopy, by using the Karl Storz 15 Fr. MiniResectoscope

ITA: Resezione di un voluminoso mioma G2, che appare come un G0 all’isteroscopia, usando il nuovo miniResettore da 15 Fr. della Karl Storz

    1 Comment

  1. I think that is possible to perform this wonderful work because:
    Miniresectoscpe 15ch can go over the cevix withe less pain .
    The new EASI pompe is a good freind in this situation we can aspirate the cervical secretions give a good controle of hemostasis withe lesse pressure.
    Bipolar energy and this generator deliver a very good kind of energy
    The loop is single use :always performe a good manipulation and bipolar energy can be used in office hysteroscopy
    The volume and the positions of mayomas in this situation is perfect
    And the very important thing is the operator a big hysteroscopist withe a high skills I had the chance to see him operate with the bipolar and in office
    with a patient who cooperates it’s perfectly possible
    Very nice song